| Key | Issue Type | Summary | Resolution | Note |
|---|---|---|---|---|
| RDNCY-183 | Bug | Redundancy Communication Page: Endless Login-Loop |
Fixed | |
| RDNCY-175 | Bug | Redundancy Communication-Page: Monitoring of Online PLCs |
Fixed | |
| RDNCY-167 | Improvement | Redundancy Configurator: Basic Validation |
Fixed | |
| RDNCY-163 | Improvement | Redundancy Configurator: BootupWaitTime |
Fixed | |
| RDNCY-162 | Bug | Swap PLC Paths should be reflected in PLC-naming in the redundancy editor |
Duplicate | [[GENERAL]] As designed. Duplicates RDNCY-80. |
| RDNCY-159 | Improvement | Redundancy editor is loosing connection to PLCs if PLC2 is in simulation and Synchronize is pushed |
Duplicate | [[GENERAL]] Duplicates RDNCY-135 |
| RDNCY-158 | Improvement | PLC1 Standalone, PLC2 Simulation: Add a note that there is a brief interruption in the fieldbus connection when switching |
Cannot Reproduce | [[GENERAL]] Obsolete, as in this state the command cannot be executed anymore, see RDNCY-157 |
| RDNCY-157 | Improvement | Redundancy Configurator: Enable / Disable Command Buttons |
Fixed | |
| RDNCY-155 | Bug | Unhandled Exception during Update Device |
Fixed | |
| RDNCY-154 | Bug | Redundancy: Unandled Exception when reopening a Project with a saved open Redundancy Configuration window |
Cannot Reproduce | [[GENERAL]] Not reproducable with SP21 P4 + Redundancy 4.2.0.0,. There is no exception -> Cannot reproduce |
| RDNCY-152 | Bug | Redundancy: after the rebooted, the status in the redundancy configuration is always unknown |
Won't Fix | [[GENERAL]] If the runtime is rebootet then an error message is shown as the connection is lost. Then the green circle in the toolbar is disabled and there is no communication until the green circle is pushed again. This is the same behavior as the in the logger page and also the application handling. If the connection is lost then the user has to reconnect manually. Therefore won't fix. |
| RDNCY-150 | Improvement | Redundancy, Redundancy Configuration: The configured controllers in relation to each other must be checked for plausibility |
Fixed | |
| RDNCY-145 | Improvement | Redundancy, Unclear configuration: When and why can the user set the 'Data sync always' option |
Fixed | |
| RDNCY-143 | Improvement | Redundancy, Redundancy Settings, General: EtherCAT configuration must be checked for plausibility |
Fixed | |
| RDNCY-142 | Improvement | Redundancy, Redundancy Settings, General: 'Read' and 'Write' buttons must be presented more prominently to the user |
Fixed | |
| RDNCY-136 | Improvement | The checkbox AutoSyncEnabled should be checked by default |
Fixed | |
| RDNCY-135 | Improvement | Refresh button for redundancy state must be pressed repeatedly |
Cannot Reproduce | [[GENERAL]] Tested with Redundancy Configurator Version 4.3.0.0 CurDev 215. Refresh button remains pressed. |
| RDNCY-133 | Bug | Update Project Environment: CompatibleVersions leads to exception "Index out of the bounds of the array" |
Fixed | |
| RDNCY-131 | Improvement | Disable data sync always checkbox with new devdesc only after user unchecks it for existing projects |
Fixed | |
| RDNCY-124 | Improvement | Implementation: WebVisu with Redundancy SL possible on more than one network adapter |
Fixed | [[GENERAL]] Implemented support for configuration of multiple IP adresses or hostnames in the visu redundancy editor. [[COMPATIBILITY_INFORMATION]] In order to use the new features at least Visualization addon version 4.9.0.0 is required. Before Visualization 4.9.0.0 the old feature set is used. |
| RDNCY-121 | Improvement | Rename package to "CODESYS Redundancy Configuration" |
Fixed | [[GENERAL]] The package has been renamed to "CODESYS Redundancy Configuration" |
| RDNCY-120 | Improvement | RedundancyDataTransfer: remove unused CAA library reference |
Fixed | |
| RDNCY-111 | Improvement | Redundancy Configuration Editor: Editor size should be dynamically adjusted to window size |
Cannot Reproduce | [[GENERAL]] Tested with V4.3.0.0 CurDev 218 |
| RDNCY-104 | Bug | Redundancy: Wrong tooltip message of Timeout in Redundancy Configuration |
Fixed | |
| RDNCY-80 | Improvement | Redundancy Configuration: Swap PLC Paths should also swap the designation PLC 1 / 2 |
Won't Fix | [[GENERAL]] As designed. The idea of this function is not to simply exchange the position of the PLC (left and right or PLC 1/2) within this editor. PLC 1 has a special role: Download and login is only possible on PLC 1. So by executing the "swap" function, PLC 2 shall become the new PLC 1! This function may anyway get obsolete with RDNCY-174 (=> no more special handling for PLC with role 1/2) |
| RDNCY-31 | Improvement | Redundancy Communication-Page: Position of Refresh Button |
Fixed | |
| RDNCY-30 | Improvement | Write / Read PLC Settings should be better visible |
Duplicate | [[GENERAL]] Duplicates RDNCY-142 |
| RDNCY-29 | Improvement | Redundancy: Inform user in redu dialog if connected to the same device |
Duplicate | [[GENERAL]] Duplicates RDNCY-150. (see screenshot) |
| RDNCY-13 | Improvement | Redundancy: Possibility to register cyclic synchronized area in configurator. |
Cannot Reproduce | [[GENERAL]] Cannot be reproduced with Redundancy V4.2.0.0 |