| Key | Issue Type | Summary | Resolution | Note |
|---|---|---|---|---|
| PN-1004 | Bug | TCI Integration: Online Communication Fails with 64 Bit CODESYS |
Fixed | |
| PN-1002 | Bug | TCI Integration: Online Communication Fails |
Fixed | |
| PN-1000 | Bug | Profinet Controller: Conformance Test V2.46 |
Fixed | |
| PN-980 | Bug | Profinet Device (Programatic Config): Multiple Start/Reset causes Exception |
Fixed | |
| PN-975 | Bug | Profinet Controller (IEC): Initial Abort Alarm not Received |
Fixed | |
| PN-973 | Improvement | Profinet: VLAN-Priority |
Fixed | |
| PN-969 | Bug | Profinet Device (Programmatic Config API): Dynamic Module Reconfiguration Fails |
Fixed | |
| PN-965 | Improvement | Profinet Device: Reduce Stack Size |
Fixed | |
| PN-964 | Bug | Profinet Controller (CIFX): IO-Link-Output Data Fail |
Fixed | |
| PN-958 | Bug | Profinet Controller: Diagnosis Inconsistent After Re-Parameterization |
Won't Fix | [[GENERAL]] This is an issue with this specific (hardware related) setting of this device. The behaviour of the diagnosis is OK for the same device if a different setting (e.g. "Diagnosis wirebreak" = ON/OFF) is used: The diagnosis appears, then disappears. |
| PN-955 | Bug | Profinet Controller: Standard-AR for Re-Parameterization |
Fixed | |
| PN-946 | Bug | GSDML-Import: Renewing the Device Repository takes an extremly Long Time |
Fixed | |
| PN-934 | Improvement | Profinet (IEC): Use new SysEthernetBurst Library |
Fixed | |
| PN-932 | Improvement | Profinet : Support Embedded Plattforms |
Fixed | |
| PN-928 | Bug | Security issues in System.Data.SQLite versions before 2.0.2 containing SourceGear.sqlite3 3.50.4.2 |
Fixed | |
| PN-925 | Improvement | Profinet Configurator: Support GSDML V2.46 |
Fixed | |
| PN-922 | Bug | System.Data.SQLite.1.0.119.0 must not be installed in the LAC |
Fixed | |
| PN-921 | Bug | Profinet Scan: Import of Module Resets Communicaton Settings |
Fixed | |
| PN-919 | Bug | Profinet Controller (IEC): Parameterization Fails for Devices with Re-Parameterization Support |
Fixed | |
| PN-918 | Bug | Profinet Controller (IEC): Unnecessary Re-Parameterization |
Fixed | |
| PN-916 | Bug | Profinet: Diagnosis Ressources show corrupted Error-Message |
Fixed | |
| PN-912 | Bug | Profinet Controller (IEC): Second Application Resets IO-Data |
Cannot Reproduce | [[GENERAL]] Cannot be reproduced. |
| PN-910 | Bug | Profinet Controller (IEC): Invalid Ident-Req by Long Station-Names |
Fixed | |
| PN-909 | Bug | Profinet Scan: Perfomance Issue with Unreachable Devices |
Fixed | |
| PN-907 | Bug | ProfinetCommon-Library: IMData_Write Uses Wrong Date-Value |
Fixed | |
| PN-897 | Bug | Linux: Reconfigure right after startup can lead to permanent PNIO: Invalid state |
Fixed | |
| PN-892 | Improvement | Profinet Controller: Avoid Flooding with Log-Messages |
Fixed | |
| PN-879 | Bug | Profinet (IEC): Invalid Calls of SysEthernetFrameRelease |
Fixed | |
| PN-866 | Improvement | Remove outdated and redundant CHM-based Online Help from AddOn package |
Fixed | |
| PN-857 | Bug | Logical I/Os: Update Device removes linked Physical I/O mapping without possibility to relink them |
Won't Fix | [[GENERAL]] see discussion linked CAP: Behavior is "as designed" as the vendor changed F-Parameters. If the F-Device still matches (IO-Data, -Parameters...), the link to the logical device remains. |
| PN-794 | Improvement | Profinet: Library Properties for Online Help |
Fixed | |
| PN-768 | Bug | Profinet Controller (IEC): Reconfigure Fails |
Fixed | |
| PN-648 | Epic | Profinet Topology Editor |
Fixed | |
| PN-605 | Bug | PS devices: GSDML import reports error with submodules GSDML error 11 |
Cannot Reproduce | [[GENERAL]] Cannot reproduce with CODESYS 3.5.21.40 and PN V4.7.2.0 |
| PN-325 | Bug | Profinet Controller (CIFX): Acknowledge Diagnosis Fails (Disabled Devices) |
Fixed |