Key | Issue Type | Summary | Resolution | Note |
---|---|---|---|---|
PN-860 | Bug | Profinet Configurator: Scan-Dialog - Read I&M Data fails |
Fixed | |
PN-858 | Improvement | Profinet Controller (IEC): Online-Services in Application-Stop |
Fixed | |
PN-856 | Improvement | ProfinetCommon - Library: Move FB UpdateDiagnosisEntry (Usability) |
Fixed | |
PN-841 | Improvement | Profinet Controller (IEC): Data-Valid Signal for Devices |
Fixed | |
PN-840 | Improvement | Profinet: GSDML Import shall create PROFIsafe Status-/Control -Byte |
Fixed | |
PN-839 | Improvement | Profinet Controller (IEC): IO-Data Buffer Handling |
Fixed | |
PN-834 | Bug | Placeholder Device: Add "supportPlaceholderObjects="true" to Submodule Connector |
Fixed | |
PN-832 | Improvement | Support of EL6633 |
Fixed | |
PN-831 | Improvement | Profinet Configurator: Redirect Pre-Selection of Update Dialog (Usability) |
Fixed | |
PN-825 | Bug | Profinet Controller IEC): Instable Startup |
Fixed | |
PN-821 | Bug | Profinet Configurator: Exeption using "Generate PROFINET Device from GSDML" with Invalid File |
Fixed | |
PN-812 | Improvement | Profinet Controller: Diagnosis-Icon for PROFIsafe Diagnosis |
Fixed | |
PN-808 | Improvement | Profinet Scan-Dialog: Column Device-Type |
Fixed | |
PN-805 | Improvement | Profinet Controller (IEC): Log-Message for Abort-events (Usability) |
Fixed | |
PN-802 | Improvement | Profinet Scan-Dialog: No safety module found if network is scanned |
Won't Fix | [[GENERAL]] The plugging rules that are defined in the GSDML do not match the real device, see CAP-264. |
PN-801 | Bug | Profinet Configurator: Exception in Topology Import |
Fixed | |
PN-791 | Improvement | Profinet Configurator: Status Page - Improved Diagnosis Messages |
Fixed | |
PN-790 | Bug | Profinet Controller: Invalid Diagnosis Data (ExtChannelError) |
Fixed | |
PN-786 | Improvement | Profisafe: Create logical device description for Safety in case a Profisafe Module is in GSDML |
Duplicate | |
PN-785 | Bug | Profinet Controller: Input Data Not Updated |
Fixed | [[GENERAL]] Caused by PN-213 |
PN-784 | Bug | Profinet Configurator: Wrong TCI / Device Tool Commands |
Fixed | |
PN-780 | Bug | Profinet Configurator: TCI / Device Tool Commands for Submodule Devices |
Fixed | |
PN-779 | Improvement | Profinet Configurator: 'Disappear' Alarm Messages (Useablility) |
Fixed | |
PN-777 | Bug | Profinet Controller: Port-Extension Modules |
Fixed | |
PN-776 | Bug | Profinet (IEC): LLDP Reports Wrong Auto-Neg |
Fixed | |
PN-746 | Improvement | Profinet Controller(IEC): Provider-State Flag |
Fixed | Run a PN project with some slave. Use setting "Update IO while in stop" Stop Appllication. Check in wireshark: ProviderState is "Stop" |
PN-735 | Bug | Security issues in System.Data.SQLite.Core versions before 1.0.119.0 containing sqlite 3.46.1 |
Fixed | |
PN-711 | Improvement | Profinet Configurator: Use Checkbox for Settings of Bit Data Type |
Fixed | |
PN-684 | Bug | Change default library to new Vendor name |
Cannot Reproduce | [[GENERAL]] no known problems in current released versions (>= 4.6.0.0) |
PN-674 | Bug | Profinet Configurator / GSDML Import: Create Logical Devices for DAP |
Fixed | |
PN-604 | Bug | PROFIsafe: Import of PROFINET module with multiple PROFIsafe Submodules fails |
Cannot Reproduce | [[GENERAL]] Canot be reproduced with V3.5 SP20 |
PN-512 | Improvement | GSDML Import with more Options for Logical Devices |
Fixed | |
PN-506 | Bug | Profinet Configurator: Status Page opens in Offline Mode |
Duplicate | [[GENERAL]] duplicates PN-405 |
PN-405 | Bug | Profinet Configurator: Status Page remains in Offline Status |
Fixed | |
PN-337 | Improvement | Profinet Controller (IEC): Online-Change for Module Settings |
Fixed | |
PN-235 | Improvement | Profinet Configurator: Status Page shall display Severity |
Fixed |