| Key | Issue Type | Summary | Resolution | Note |
|---|---|---|---|---|
| COMM-1456 | Improvement | Update to UA.Net nuget references to latest version (1.5.378.134) |
Fixed | [[GENERAL]] The UA-.NETStandard stack has been updated to version 1.5.378.134 |
| COMM-1455 | Bug | OPC UA PADIM model: Can not be used as information model |
Cannot Reproduce | [[GENERAL]] Was a bug within the used .net OPC UA stack. Was fixed during the update to the latest version of the .net OPC UA stack. |
| COMM-1406 | Bug | IecSymbolPublishing: Alarms of type REP should not be detected as incompatible to OPC UA clients |
Fixed | |
| COMM-1403 | Bug | Datasource, Onlinechange: Online change for change of comm settings possible without activating |
Fixed | [[COMPATIBILITY_INFORMATION]] Accidentally some modifications in the communication settings of datasources where possible without active Datasource Online Change functionality in the programming system, e.g. by having a supporting device description. These changes will now also trigger a download when the Datasource Online Change functionality in the programming system is inactive. The license check was always executed at runtime. |
| COMM-1395 | Bug | IECSymbolPublishing: Endless recursion when using variable of recursive alias type. |
Fixed | |
| COMM-1390 | Bug | Nodeset Export: Exception in export |
Fixed | |
| COMM-1389 | Bug | Datasources: Compile errors in 3.5 SP22 after copy/paste/delete/paste |
Fixed | |
| COMM-1388 | Bug | SymbolConfig: Symbolconfig LM is different between Compile- and PreCompile-Context |
Won't Fix | [[GENERAL]] The customer plugin in this project configures the symbolconfiguration with wrong data. The customer must take care to pass ALIAS values resolved and not as a userdef type. And must pass VAR_INOUT variables as normal variables with type REFERENCE TO. If this does not happen the code generated by the symbol configuration does not match the code generated by the compiler and will lead to the wrong behaviour described in the issue. |
| COMM-1377 | Improvement | Placholder is resolved incorrectly for CmpOPCUAStack Implementation |
Fixed | |
| COMM-1376 | Bug | Compiler: Internal error while object is providing language model information |
Fixed | |
| COMM-1375 | Bug | Download hangs in simulation mode when "Use access rights defined in the user management" is active |
Won't Fix | [[GENERAL]] Is a bug within the simulation runtime itself. Will be fixed with CDS-97242 |
| COMM-1372 | Bug | Datasource OPC UA: stack overflow detected after update COMM version to 4.7.0.0 |
Fixed | |
| COMM-1371 | Bug | PERSISTENT variables and PERSISTENT RETAIN variables cannot be published in IEC Symbol Set Configuration |
Won't Fix | [[GENERAL]] This issue will not be fixed, as there is special instructions are generated when VAR PERSISTENT RETAIN or VAR PERSISTENT is accessed via IEC-Code. This behavior cannot be done within the corresponding libraries. Therefor this feature will not be implemented. |
| COMM-1370 | Bug | IECSymbolPublishing: Array of FB not supported |
Fixed | [[GENERAL]] Array of FB is not supported, as there is no proper equivalent in the UA world. Proper warnings are now generated, if this is used. |
| COMM-1363 | Bug | OPC UA Client, Datasource: Browse does not work with CA-certificates |
Fixed | |
| COMM-1351 | Improvement | Datasource, Onlinechange: Support on SL-runtimes |
Fixed | [[GENERAL]] For devices that support the PLC Setting "enable online configuration change", this setting can also be used now for activating onlinechange functionality of Datasources. The according license on the PLC is always necessary when executing online changes on Datasources no matter how the functionality was enabled. |
| COMM-1347 | Bug | OPC UA information model editor: F1 Onlinehelp link to editor articles does not work |
Cannot Reproduce | |
| COMM-1335 | Improvement | Datasources: Prepare for ElementCollections within BASLIB 5 |
Fixed | |
| COMM-1332 | Bug | Symbol Set: Alarm Group editor: Export creates different ConditionID than shown in UaExpert |
Fixed | |
| COMM-1057 | Improvement | OPC UA Datasource: Implement IOPCUAClientConnectionCallback2 to use improved certificate validation |
Fixed | |
| COMM-987 | Improvement | Information model: Add warnings for unsupported datatypes types and VAR_IN_OUT |
Fixed | |
| COMM-704 | Bug | Comm, UA Server, IEC Symbol Set Editor: Comment not updated for existing Symbol |
Fixed |